Antimony in Well Water: The Public 0.006 mg/L Line

By SubcontractorHub Editorial Team·Published October 2026

Antimony in well water read against the public 0.006 mg/L line

Quick Answer

Antimony in well water is read against a public MCL of 0.006 mg/L, and the MCLG cell prints 0.006 as well. The source cell names petroleum refineries, fire retardants, ceramics, electronics, and solder. A private well is not that public-system rule. Book a demo to keep the lab row on the customer file.

A metals panel can list several names on one page. The digit next to antimony is not the digit next to cadmium, and it is not the digit next to beryllium. Dealers who sell treatment still have to say which public line they are reading. SubcontractorHub is software for the customer record. This page is the row. It is not a treatment design.

The Public 0.006 mg/L Line for Antimony in Well Water

The national primary drinking water regulations are legally enforceable primary standards and treatment techniques that apply to public water systems. In the inorganic block, antimony shows an MCLG of 0.006 and an MCL of 0.006. The potential health effects cell says increase in blood cholesterol and decrease in blood sugar. The source cell says discharge from petroleum refineries, fire retardants, ceramics, electronics, and solder.

Footnote 2 says units are in milligrams per liter unless otherwise noted, and that milligrams per liter are equivalent to parts per million. 0.006 mg/L is therefore 0.006 ppm on that note. It is not a second standard hiding under a different name. Moving the same digits to micrograms per liter uses the 1,000-to-1 scale on milligrams and micrograms. 0.006 mg/L is 6 µg/L on that scale. Write both labels if the lab used the smaller unit, so a later reader does not think 6 is a new limit.

An MCLG is a goal. An MCL is the enforceable public number. On this row the two cells print the same digit. That match is not true of every neighbor. The definitions of those two words are on MCL and MCLG. A goal is not a fine, and a matching pair is still one line.

The 0.006 mg/L Figure in the Inorganic Table

Section 141.62, as printed on the Cornell eCFR page fetched the same day, lists maximum contaminant levels for inorganic contaminants. Antimony is item (11), at 0.006 mg/L. Cadmium, earlier on that table, is 0.005 mg/L. Beryllium, the next item, is 0.004 mg/L. Those are not one number. The cadmium row has its own page, cadmium in well water. The beryllium row has its own page, beryllium in well water.

Paragraph (b) says the levels in items (11) through (16), which include antimony, apply to community and non-transient, non-community water systems. A private well is not named in that sentence. A dealer who copies the 0.006 mg/L line onto a kitchen-tap jug still has to say the jug is not the public-system rule. The difference between a city system and a private well is what is a public water system.

Antimony in Well Water Is Not the 0.005 mg/L Row

Cadmium prints 0.005 mg/L on the same national table, with a health cell that says kidney damage and a source cell that names galvanized pipes, natural deposits, metal refineries, and waste batteries and paints. That is a different metal and a different source sentence. Chromium (total) prints 0.1 mg/L, on chromium in well water. Barium prints 2 mg/L, on barium in well water. Do not paste a battery sentence onto the antimony row because the words sound related to a metals panel.

The source sentence you are allowed to repeat from this fetch is petroleum refineries, fire retardants, ceramics, electronics, and solder. If the lab header says antimony, that is the source cell. Adding the neighbors together is not the rule this page fetched.

What the Note Holds, and What It Does Not

LineWrite thisDo not write this
ContaminantAntimonyCadmium, or beryllium
MCLG0.006 mg/LA goal borrowed from a neighbor
MCL0.006 mg/L0.005 mg/L or 0.004 mg/L
Rule item(11) on the inorganic tableA blank cell
Health cellIncrease in blood cholesterol; decrease in blood sugarA medical opinion
Source cellPetroleum refineries; fire retardants; ceramics; electronics; solderA battery or a paint, unless the sheet says so
BAT marks2 and 7: coagulation/filtration, and reverse osmosisA removal percent
Who the rule namesCommunity and non-transient, non-community systemsA private well

The table above is the note. It is not a quote, and it is not a removal design. A customer who wants a price still needs a test, a model, and a scope. Those live on the job. This page only stops the wrong digit from landing in the scope.

What the BAT Marks Do Not Promise

The BAT table on the same Cornell page marks antimony as 2 and 7. The key says 2 is coagulation and filtration, and that this technology is not BAT for systems with fewer than 500 service connections. The key says 7 is reverse osmosis. Those marks identify a technology the rule names for compliance with the MCL. They do not say what percent a cartridge in a basement will remove.

A city plant and a point-of-entry tank are not the same machine. If you sell reverse osmosis, say you sell reverse osmosis. Do not say the number 7 is a guarantee on this well. No removal percentage was fetched for this row, so none is printed here. Beryllium, on the same technology table, carries a longer list of marks. That difference is another reason not to copy one metal's marks onto the other.

What Should the Antimony in Well Water Note Say?

Five lines keep the next visit from borrowing a neighbor. Name the metal the lab printed, show the unit before anyone compares it with 0.006, and say whether the jug is a private well. If a line does not apply, mark it skipped. A blank line looks the same as a step you forgot, and a skipped line is still a line someone can read later.

  1. The metal name as the lab printed it, antimony, not a panel total.
  2. The result and the unit. If the unit is µg/L, show the mg/L equivalent on the 1,000 scale before anyone compares it with 0.006.
  3. The public pair you compared it with: MCLG 0.006 mg/L and MCL 0.006 mg/L, named as the national antimony row.
  4. Whether the sample is a private well or a public system. Paragraph (b) names community and non-transient, non-community systems for this item.
  5. What you did not claim: no removal percent, no installed price, and no statement that 0.006 mg/L is cadmium's 0.005 mg/L.

Where the Row Sits on the Job

The lab sheet belongs with the customer, the address, and the date of the sample. A price for equipment is a later page, after someone has read this row and the rows next to it. Mixing the 0.006 mg/L line into a softener quote because the panel listed several metals skips the chemical name.

How a dealer reads a full panel, including which tests were actually run, is the well water testing guide. The software that holds the customer file is water treatment contractor software. This article does not size a filter and does not tell a household the water is safe to drink.

Frequently Asked Questions

What is the public line for antimony in well water?

On the national primary table, antimony shows an MCLG of 0.006 mg/L and an MCL of 0.006 mg/L. The inorganic table names the same contaminant at 0.006 mg/L. A private well is not the public system that sentence regulates.

Is 0.006 mg/L the same number as cadmium?

No. Cadmium on the same national table is 0.005 mg/L. Beryllium is 0.004 mg/L. Sharing a neighborhood on the inorganic block is not sharing a digit.

What health effect does the national table list?

The potential health effects cell says increase in blood cholesterol and decrease in blood sugar. That is the cell on the fetched table. It is not a diagnosis of the person who handed you the jug.

Do the BAT numbers mean a removal percent?

No. The inorganic BAT row for antimony is marked 2 and 7. The key names coagulation and filtration, and reverse osmosis. A mark is not a percent removed from a private well.

Should the dealer add antimony to cadmium?

No. Cadmium is 0.005 mg/L on its own row. Adding 0.006 and 0.005 does not create a limit the rule printed. Write the metal the lab named.

Save the 0.006 mg/L Row With the Sample

The metal name, the unit, and whether the jug is a private well belong on the customer record. Book a demo and walk one lab sheet onto that file.