Calcite Neutralizer Media: What Clack Form 2386 Prints

By SubcontractorHub Editorial Team·Published November 2026

Crew planning a calcite neutralizer media refill from a manufacturer sheet

Quick Answer

Calcite neutralizer media, on Clack form 2386 fetched 20 November 2026, is listed at 90 pounds per cubic foot. The order line prints a 50-pound bag as 0.55 cubic foot. Bed depth is 24 to 30 inches, and freeboard is at least 50 percent of that bed depth. The sheet says the bed is replenished as it depletes. It does not print a month.

Tank size from peak flow is a different page. The acid neutralizer sizing calculator uses a planning density of about 100 pounds per cubic foot and calls a 50-pound bag about half a cubic foot. This article quotes the manufacturer sheet instead of that planning round number. It does not change the calculator.

What Calcite Neutralizer Media Is on Form 2386

Clack form 2386, dated 19 September 2019 on the sheet and fetched from Clack's site on 20 November 2026, says calcite is a crushed and screened white marble media used to neutralize acidic or low pH waters to a neutral, less corrosive effluent. It calls the material naturally occurring calcium carbonate. One advantage it names is a self-limiting property: when properly applied, it corrects pH only enough to reach a non-corrosive equilibrium, and it does not overcorrect under normal conditions.

On contact, acidic water slowly dissolves the calcium carbonate, which raises pH and, the sheet says, reduces the potential leaching of copper, lead, and other metals found in typical plumbing. That sentence is about the plumbing metals. It is not a removal claim for a contaminant already in the well at a stated concentration. The low-pH discussion that is already on this site stays on acidic well water and well water pH. This page is the media sheet those articles do not quote.

The Bag, the Density, and the Bed

Physical properties list color as near white, bulk density as 90 pounds per cubic foot, mesh 16 by 40, specific gravity 2.7, effective size 0.4 mm, uniformity coefficient 1.5, and Mohs hardness 3.0. Composition is CaCO3, 95 percent minimum, and MgCO3, 3.0 percent maximum. The order block for part A8021-01 prints 0.55 cubic foot per bag at 50 pounds, 90 pounds per cubic foot with an asterisk that the weight per cubic foot is approximate, 49 bags per pallet, a pallet weight of 2,486 pounds, and pallet dimensions of 48 by 40 by 32 inches.

Conditions for operation: a gravel support bed is recommended. Water pH range is 5.0 to 7.0. Bed depth is 24 to 30 inches. Freeboard is 50 percent of bed depth, minimum. Backwash rate is 8 to 12 gallons per minute per square foot. Backwash bed expansion is 12 percent minimum. Service flow is 3 to 6 gallons per minute per square foot, and the sheet says that service rate may be modified to adapt to local conditions.

Fifty percent of a 24-inch bed is 12 inches of freeboard, and 50 percent of a 30-inch bed is 15 inches. That arithmetic is the sheet's percent applied to the sheet's bed depths. It is not a fill line for a tank model the sheet does not name. Do not fill from a dealer's "two-thirds full" sentence unless you fetched that dealer's manual. Those startup guides were seen in search on 20 November and were not used for a number.

LineWhat form 2386 printsNote
Bulk density90 lb per cubic footPhysical properties. The order asterisk says weight per cubic foot is approximate.
Bag0.55 cubic foot (50 lb)Part A8021-01. 49 bags per pallet. Pallet weight 2,486 lb.
Mesh and size16 x 40. Effective size 0.4 mmUniformity coefficient 1.5. Specific gravity 2.7. Mohs hardness 3.0.
CompositionCaCO3 95% minimum. MgCO3 3.0% maximumColor: near white.
BedDepth 24–30 in. Freeboard 50% of bed depth, minimumA gravel support bed is recommended.
FlowService 3–6 gpm per sq ft. Backwash 8–12 gpm per sq ftBackwash bed expansion 12% minimum. Service rate may be modified for local conditions.
pHWater pH range 5.0–7.0The sheet says calcite does not overcorrect under normal conditions when properly applied.
After the filterHardness increases. A softener may be neededDoes not remove or kill bacteria. NSF/ANSI/CAN 60. Maximum usage 650 mg/L for the named marble.

Hardness Goes Up, and Bacteria Are Not Removed

The sheet says that as the calcium carbonate neutralizes the water, hardness increases, and a softener may become necessary after the neutralizing filter. Size that softener on the hardness measured after the neutralizer. The water softener sizing calculator already says that. This page does not redo the grain math.

The closing block says the filter medias in the brochure do not remove or kill bacteria, and not to use them with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. A calcite bed is not a coliform answer. The sheet is certified to NSF/ANSI/CAN Standard 60. It names Calcium Carbonate XO White, manufactured by Imerys Marble Inc., with a maximum usage of 650 mg/L.

Periodic backwashing, the sheet says, prevents packing, reclassifies the bed, and maintains high service rates. Depending on pH, water chemistry, and service flow, the bed will have to be periodically replenished as the calcite is depleted. "Periodically" is the word on the sheet. No month and no percent-dissolved trigger were printed, so none are added. The sizing calculator's 30 percent top-up fraction is that tool's planning assumption. It is not form 2386.

Corosex Is Named, and It Is Not Given a Blend Recipe Here

The sheet says calcite can be combined with Clack Corosex to combine Corosex's high-flow neutralization with calcite's slower low-flow reaction, increasing the ability to correct low pH. It does not, on the pages fetched, print a pound ratio for that blend. A 90-pound and 10-pound mix seen on a dealer startup PDF was not quoted. If the job uses a blend, the ratio has to come from the sheet in the box, not from this article.

What to Write Down Before You Order Calcite Neutralizer Media

  1. Record the raw pH. The sheet's operating range is 5.0 to 7.0. Outside that range, this page does not invent a substitute media.
  2. Record bed depth and the freeboard you will leave. Minimum freeboard on the sheet is half the bed depth.
  3. Check service flow and backwash against 3 to 6 and 8 to 12 gallons per minute per square foot. The service line says local conditions may change it. Write the change if you make one.
  4. Order from the bag the sheet prints: 50 pounds, 0.55 cubic foot, about 90 pounds per cubic foot. Do not swap in the calculator's 100-pound planning density and call it Clack.
  5. Plan a softener after the filter if the added hardness matters. Do not claim the calcite bed softened the water.
  6. Disinfect if bacteria are in the test. The sheet says this media does not kill them. No bag price was on the form, so none is printed.

Demand for this URL is the public search for a calcite refill number that the sizing tool rounds. Ahrefs was not refreshed. The pressure-drop curves on the PDF were not read off as a single psi figure, because the extraction did not give a clean table of pounds per square inch at a stated flow. No psi drop is invented here.

Frequently Asked Questions

What is calcite neutralizer media on the Clack sheet?

Clack form 2386, fetched 20 November 2026, calls calcite a crushed and screened white marble media used to neutralize acidic or low pH water. Composition is CaCO3, 95 percent minimum, and MgCO3, 3.0 percent maximum. Bulk density is 90 pounds per cubic foot. The order line says one bag is 0.55 cubic foot at 50 pounds.

What bed depth and freeboard does that sheet print?

Conditions for operation list a bed depth of 24 to 30 inches and freeboard of 50 percent of bed depth, minimum. A gravel support bed is recommended. The sheet does not convert those inches into a bag count for a named tank diameter. This page does not either.

What flow rates are on the sheet?

Service flow is 3 to 6 gallons per minute per square foot, and the sheet says that rate may be modified to adapt to local conditions. Backwash is 8 to 12 gallons per minute per square foot. Minimum backwash bed expansion is 12 percent. Those are the sheet's rates, not the planning rates on this site's acid-neutralizer calculator.

Does calcite neutralizer media replace a softener?

The sheet says that as calcium carbonate neutralizes the water, hardness increases, and a softener may become necessary after the neutralizing filter. It also says the media does not remove or kill bacteria. A pH correction and a hardness reduction are different stages.