An HVAC capacitor on a residential condenser is the part that has to match the label, not a nearby microfarad a truck happens to carry. Cornell Dubilier's Type SF dual catalog, fetched 27 November 2026, builds two capacitances into one can, from 15–5 µF to 80–10 µF, at 370 Vac or 440 Vac, with a standard tolerance of ±10 percent.
This page is the part, written for the tech who writes the ticket. It is not a homeowner how-to and it is not a price list. No capacitor dollar was on either page fetched today. Ahrefs (pulled 2026-11-27) lists hvac capacitor at 2,900 monthly searches in the United States, keyword difficulty 0, traffic potential 4,700, and a cost per click of 10 cents.
The CDE sheet says a dual rated oil-filled motor run capacitor puts two capacitors in one can. One section may run a fan. The other may run a compressor or a motor. Three terminals let one terminal act as the common. The part number on that sheet encodes the two microfarad values, the voltage, and the tolerance. A 45-5 at 440 Vac is not the same catalog line as a 40-5, and the sheet prints both.
| Item | What the CDE Type SF sheet printed |
|---|---|
| Capacitance range | 15–5 µF to 80–10 µF, two sections in one can |
| Standard tolerance | ±10 percent. ±6 percent and ±3 percent are available |
| Rated voltage | 370 Vac and 440 Vac |
| Temperature | −40 ºC to 70 ºC, with ripple |
| Life objective | 60,000 hours, 94 percent survival, at rated voltage, 60 Hz, and rated ambient |
| Terminals | Three. One is common to both sections |
Capacitance on that sheet varies by no more than ±3 percent across the operating temperature range. That is a temperature drift, not the tolerance you order. The order tolerance is the ±10 percent standard, or the tighter ±6 or ±3 if that is the part. Ferguson's guide, also fetched 27 November 2026, says most HVAC capacitors fall in a range of about 5 to 80 microfarads, which lines up with the top of the CDE dual range and goes lower than the 15–5 floor of that particular dual series.
Ferguson says a capacitor more than about 10 percent above the required microfarads can still run and can wear the compressor faster, and that a value too low may not start the motor or may start it slowly. The same guide says a higher voltage rating can replace a lower one and a lower rating must not replace a higher one. Replacing 370V with 440V is the example it prints. The CDE catalog does not print that sentence. Use it as Ferguson's rule, then confirm it against the equipment label.
The call that only adds the lines the tech types is the HVAC service call cost calculator. A failed part next to a wider symptom list is the HVAC troubleshooting chart. The van stock that should include a meter and the common cans is the HVAC tools list.
A capacitor is a service ticket, not a system replacement. The HVAC replacement cost calculator is the changeout page. Do not paste a condenser price onto a 45/5 replacement. Flat-rate books that already price the repair live with the shop's own book. This article does not add a task price to one.
Public search on 27 November 2026 for the head query returned Ferguson's trade guide, a Trane heat-pump capacitor page, a Home Depot replacement article, a meter-test page, and Carrier's residential capacitor explainer. Those are parts and homeowner explainers. The contractor version is the label match and the line on the invoice. No new software URL is opened here.
A street price, a truck-stock count, and a microfarad per ton were not on the pages that were fetched. The CDE life figure is 60,000 hours at rated conditions with a 94 percent survival rate. It is not a warranty for the can on a roof in July. Ferguson names overheating and age as failure reasons on the trade page that was fetched. A bulged case is a reason to replace the part you are holding. It is not a diagnosis of the compressor.
Discharge and lockout belong to the tech who is qualified to open the cabinet. This page does not print a discharge procedure, because neither source was used as a step list. If the label is unreadable, the wiring diagram is the next document, not a guess from the tonnage.
Cornell Dubilier's Type SF dual catalog, fetched 27 November 2026, rates a dual run capacitor as two capacitances in one can, from 15–5 µF to 80–10 µF, at 370 Vac or 440 Vac. The standard tolerance on that sheet is ±10 percent, with ±6 percent and ±3 percent available. Match the microfarads on the label. Do not pick a nearby value.
Ferguson's AC capacitor guide, fetched the same day, says you can replace a capacitor with a higher voltage rating and never with a lower one, and gives 370V replaced by 440V as the example. The CDE catalog lists both voltages as ratings. It does not itself print that replacement rule. The equipment label still decides.
The CDE Type SF sheet says ±10 percent is standard, and that ±6 percent and ±3 percent are available. Ferguson says a microfarad rating more than about 10 percent high can still run the compressor and can wear it faster. Read the tolerance printed on the can you are replacing. This page does not invent a single percent for every brand.
No capacitor price was fetched today, so none is printed. The part line belongs on the flat-rate or the service invoice with the microfarads, the voltage, and the labor you actually used. The service-call calculator on this site adds the dollars the visitor types. It does not store a capacitor price.
The label is the part number. The ticket should show the same numbers.