Reverse Osmosis Reject Water: Recovery Is Not Efficiency

By SubcontractorHub Editorial Team·Published November 2026

Installer reviewing a reverse osmosis reject water rating before writing it on the job

Quick Answer

Reverse osmosis reject water is the stream a membrane does not keep. The Pentair GRO-350B manual fetched 20 November 2026 prints a recovery rating of 38.65 percent and an efficiency rating of 22.05 percent. Those are different tests. A Watts manual fetched the same day prints an average of 4 gallons of reject water per gallon of product. Neither number is a tank price.

The storage-tank article already quoted an empty-tank air charge and stopped when a manual said "several gallons" without a ratio. This page is the ratio, and only where a fetched sheet prints one. It does not replace the air-charge steps on the reverse osmosis storage tank.

What Reverse Osmosis Reject Water Is on the GRO-350B Sheet

The GRO-350B manual says the membrane separates pre-filtered water into product water and drain or reject water. Incoming pressure forces product water through the membrane and into the storage tank. Dissolved solids and other contaminants that cannot pass are sent to the drain. When the faucet opens, product water is drawn from the tank through an activated carbon post-filter.

The same section says that for each gallon of water produced, several gallons are discharged as reject water. That sentence does not give a count. The performance block on the same PDF does. It prints a system production rate of 14.96 gallons per day, a recovery rating of 38.65 percent, an efficiency rating of 22.05 percent, and TDS rejection of 96.9 percent. The storage tank on that manual can hold up to 2.1 gallons. The storage-tank article already used 2.1 gallons for a GRO-350BP sheet. This page does not turn 2.1 into a new capacity claim. The new lines are the two ratings.

Recovery and Efficiency Are Printed as Different Tests

The GRO-350B sheet defines efficiency rating as the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage. It defines recovery rating as the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank, or when the storage tank is bypassed.

A job note that copies only 38.65 percent has described the membrane test without the tank. A note that copies only 22.05 percent has described typical daily use of the system. Calling either number "the waste ratio" without the definition is how a proposal overstates what the sheet measured. The sheet also says the system was tested to NSF/ANSI 58 for the substances it lists, and that substances reduced are not necessarily in the water. A quote still needs the test for that house.

Membranes, when used under the specifications on page 3 of that manual, should last 12 to 24 months. Filter-change clocks for other brands stay on reverse osmosis maintenance. The GE 75 percent TDS line stays on the membrane page. This article does not move them.

The GRO-475B English Block Is a Different Pair of Ratings

The GRO-475B manual uses the same product-versus-reject description and the same "several gallons" sentence. Its English performance block is not the GRO-350B block. It prints a production rate of 30.57 gallons per day, a recovery rating of 51.17 percent, an efficiency rating of 32.90 percent, and TDS rejection of 95.5 percent. The EPA number on both English blocks is 082989-CHN-001. Sharing an EPA number is not sharing a rating.

The Spanish performance block on the same GRO-475B PDF prints an efficiency of 30.57 percent. That figure matches the production rate's digits, not the English efficiency of 32.90 percent. This page quotes the English block. It does not average 32.90 and 30.57, and it does not pick the Spanish line because it was on the same file. A dealer who has the Spanish sheet in hand should read that sheet. A dealer quoting from this article should use the English numbers and say so.

One Watts Manual Does Print Four Gallons

The Watts H2O-DWRO300 manual says there is an average of 4 gallons of reject water for every 1 gallon of product water produced. It repeats that sentence next to the same style of efficiency and recovery definitions: efficiency under conditions that approximate typical daily usage, recovery when the system is operated without a storage tank or when the tank is bypassed. The 4-to-1 line is an average that manual states. It is not a conversion of Pentair's 38.65 percent, and this page does not do that conversion.

ManualProductionRecoveryEfficiencyOther line on that sheet
GRO-350B14.96 gpd38.65% recovery22.05% efficiency96.9% TDS rejection
GRO-475B, English block30.57 gpd51.17% recovery32.90% efficiency95.5% TDS rejection
Watts H2O-DWRO30050 gpd membrane, as that manual names itDefines recovery the same wayDefines efficiency the same wayAverage 4 gallons reject per 1 gallon product

What to Write When the Customer Asks About Reverse Osmosis Reject Water

  1. Name the model. A GRO-350B rating is not a GRO-475B rating.
  2. If you quote a percent, say whether it is recovery or efficiency, using the definition on that sheet.
  3. Do not turn "several gallons" into 3-to-1 or 4-to-1. The Watts 4-to-1 line stays on the Watts model.
  4. Leave the empty-tank air charge on the storage-tank page. This article does not restate 5 to 7 psi.
  5. Price the system on the reverse osmosis system cost calculator if you need a planning range. No reject-water price was fetched, so none is added here.
  6. A drain that cannot take the reject stream is a plumbing question, not a higher recovery number. This page does not size the drain.

Demand for this URL is the public search for a reject ratio plus the gap the 18 November storage-tank article left on purpose. Ahrefs was not refreshed. No universal gallons-per-gallon figure, no faucet air-gap height, and no membrane price are printed.

Frequently Asked Questions

What is reverse osmosis reject water?

On the Pentair GRO-350B manual fetched 20 November 2026, the membrane separates pre-filtered water into product water and drain or reject water. Dissolved solids that do not pass the membrane go to the drain. The same manual says that for each gallon produced, several gallons are discharged as reject water, and it also prints a recovery rating of 38.65 percent.

Is recovery the same as efficiency?

No. The GRO-350B performance block defines recovery as the percentage of influent water to the membrane that is available as treated water when the system is operated without a storage tank or when the tank is bypassed. Efficiency is the percentage of influent water to the system available to the user under conditions that approximate typical daily usage. On that block the two numbers are 38.65 percent and 22.05 percent.

Do the two Pentair manuals print the same ratings?

No. The English performance block on the GRO-475B manual fetched the same day prints a production rate of 30.57 gallons per day, a recovery rating of 51.17 percent, an efficiency rating of 32.90 percent, and TDS rejection of 95.5 percent. The GRO-350B block prints 14.96 gallons per day, 38.65 percent recovery, 22.05 percent efficiency, and 96.9 percent TDS rejection.

Does every system reject four gallons per gallon made?

The Watts H2O-DWRO300 manual fetched the same day says there is an average of 4 gallons of reject water for every 1 gallon of product water produced. That sentence is that manual's. It is not the Pentair recovery percentage, and it is not a ratio for a tank whose manual only says several gallons.

SubcontractorHub

See How Top Contractors Close More Jobs

AI proposals, sales pipeline, and project management — all in one platform.

  • ✓AI-powered proposals in the field
  • ✓CRM built for contractor sales
  • ✓Project tracking from sale to install
Book a Free Demo →