By SubcontractorHub Editorial Team·Published November 2026

Quick Answer
An A2L refrigerant is a lower-flammability class, not one product. ICC lists R-454B and R-32 and does not list R-410A. EPA's sector table sets a GWP limit of 700, with the dates quoted below. This is not legal or safety advice. Book a demo if the quote should name the equipment.
This page is for the contractor writing the quote, not for a homeowner shopping a cylinder. It says what the class is, how R-454B and R-32 sit inside it, and which sentences EPA and ICC actually printed. It does not tell a technician how to braze, recover, or set a leak sensor.
ICC's A2L transition page, fetched the day this was written, says A2L refrigerants have lower toxicity and flammability than A2 or A3 refrigerants. It says common refrigerants are listed in ASHRAE Standard 34. It spells the letters as A for non-toxic, 2 for flammable, and L for low burning velocity, and it calls that the second-safest category. This article uses that sentence. It does not reprint ASHRAE 34 itself.
The same page names R-1234yf, R-1234ze, R-454C, R-455A, R-454A, R-454B, R-447A, R-32, and R-452B. It says some A2L refrigerants are pure and some are blends, and that pressure, temperature, and viscosity vary by type. An A2L refrigerant on a quote is one of those names, written out, not the letters alone.
The federal card that lets a technician buy refrigerant is a different document. That split is HVAC certification, and a practice set for the test is the EPA 608 practice test. Passing the test is not the same as knowing which class is in the condenser you are quoting.
ICC's list above does not include R-410A. Johnson Controls' whitepaper on the low-GWP transition, also fetched that day, calls R-410A an A1-classified refrigerant and says mildly flammable A2L refrigerants require safety methods that A1 did not. On that paper's class table, A1 sits in the no-flame-propagation column. So the answer to the question people type, whether 410A is an A2L refrigerant, is no on these two pages.
The same Johnson Controls figure prints GWP = 2,088 next to R-410A and GWP = 466 next to R-454B. Those are that paper's numbers. They are not a price, and they are not a promise that every nameplate matches the figure. Read the nameplate on the unit you are selling.
Both names are on ICC's A2L list. They are not interchangeable words. ICC says viscosity and pressure vary by refrigerant type. Johnson Controls says the industry is migrating equipment from R-410A to R-454B or R-32, and that both are considered mildly flammable. An A2L refrigerant choice on a job is the one the equipment was built for. This page does not say you can top one off with the other.
R-454B has a GWP of 466 on the Johnson Controls timeline figure. A GWP for R-32 was not pulled into a sentence this article will stand behind, so none is printed. EPA's limit for the residential and light commercial subsector, below, is 700. A refrigerant under that limit is not, by itself, a match for a coil that was built for a different number.
| Line | R-410A | R-454B | R-32 |
|---|---|---|---|
| Class on the pages fetched | A1, Johnson Controls whitepaper | A2L, ICC list | A2L, ICC list |
| GWP printed on a fetched page | 2,088 on the Johnson Controls timeline figure | 466 on that same figure | Not quoted here |
| Same thing as the class? | No. A refrigerant name is not a class. | No. One A2L refrigerant, not the class. | No. Another name on the ICC list. |
| What this page will not say | That it is banned | A cylinder price | A charge-limit formula |
EPA's restrictions-by-sector page says that beginning January 1, 2025, certain technologies may no longer use high-GWP HFCs or HFC blends. It says prohibitions apply to manufacture, distribution, sale, installation, import, and export of products that contain restricted HFCs, and to installation of new systems that use restricted HFCs. For stationary residential and light commercial air conditioning and heat pumps, the products table prints a GWP limit of 700 and a manufacture and import date of January 1, 2025.
The systems table, for residential and light commercial air conditioning and heat pump systems such as mini-splits and unitary systems, also prints 700 and January 1, 2025, and then this clause: no installation compliance date for systems where all specified components were manufactured or imported prior to January 1, 2025. Footnote 6 says to read the Technology Transitions Reconsideration Rule for that line. Footnote 5 says EPA is restricting installation of new field-assembled systems, and that components used to repair existing systems are not subject to these restrictions.
EPA's frequent-questions page still answers a broken R-410A condensing unit this way: a homeowner can replace a faulty component with a similar R-410A component, and after January 1, 2026, if a whole new system is installed it must use a lower-GWP refrigerant. A later answer says any new split system installed after January 1, 2026 must use refrigerant with a GWP less than 700. This article quotes both EPA pages. It does not collapse them into "R-410A is banned." Servicing an existing system and installing a new system are different sentences on those pages. If a date on a bid package matters, read the rule, not this summary.
Johnson Controls' service table, for R-454B against R-410A, marks a leak detector as 2L certified, a recovery cylinder as flammable with a GHS label and a left-hand thread, and recovery machines as 2L certified. The same paper says A2L cylinders have a pressure relief valve, a red band or a red top, and a left-hand thread. Gauges, hoses, a scale, a flare tool, and a pipe cutter are marked routine on that table. This is a description of that table. It is not a procedure, and it is not a shopping list with prices. No cylinder price was fetched.
The paper also says some service equipment should be specifically designed for mildly flammable A2L refrigerants, and it names R-454B, R-1234yf, and R-32 as examples. It names UL 60335-2-40, ASHRAE 15, ASHRAE 34, and the International Mechanical Code as the standards that govern the equipment. Charge limits, dissipation, and sensor setpoints stay in the manufacturer's installation manual. They are not copied here.
A hand-tool list that was built from school lists, and that deliberately left recovery machines off because those lists did not name them, is the HVAC tools list. Do not treat this article as an extra checkbox on that list. The tool rating comes from the tool maker and from the standard the whitepaper names.
The replacement dollars, if you are pricing a system, stay on the HVAC replacement cost calculator. This checklist is the record that should sit next to that price. It is not a code inspection.
HVAC quote software on this site describes a quote built from a price catalog, with more than one equipment tier, and an installation project that is created when the customer signs, with equipment specs already on it. That is the place to write the refrigerant the tier uses. This article does not claim a separate refrigerant database, a cylinder serial log, or a recovery-pound field. Those were not on the product page.
HVAC installation software describes the signed job moving through equipment delivery and the later install steps. The refrigerant note belongs with the equipment on that job, because the crew that sets the condenser is not always the rep who sold it. HVAC contractor software is the wider product. None of those pages were rewritten to add an A2L refrigerant feature that the product does not state.
If the only thing that changed is the name on the condenser, the quote should say the name. A homeowner comparing two tiers cannot see a class letter. R-454B on one tier and a different listed A2L refrigerant on another tier are different equipment lines. Write both, or do not offer both.
No cylinder price. No "R-410A is banned" line. No step-by-step recovery. No claim that every state has adopted the 2024 mechanical code. ICC's page says the 2024 I-Codes allow A2L refrigerant use and offers amendment packets for older editions. Whether your city has adopted them is a local question. This is not legal advice and not safety advice. A tech who needs a procedure should use the equipment manual and the code the jurisdiction adopted.
A public search for R-454B the same day returned manufacturer pages, including Trane, Honeywell Solstice, a Carrier Enterprise note, the Johnson Controls paper quoted above, and Chemours Opteon XL41. Only the Johnson Controls paper was fetched for a GWP. Opteon was seen in the list and not quoted, so 466 is only the Johnson Controls figure.
ICC's A2L transition page lists R-1234yf, R-1234ze, R-454C, R-455A, R-454A, R-454B, R-447A, R-32, and R-452B. It says some are pure and some are blends. That list is what this page uses. It is not a complete ASHRAE 34 table.
Not on the pages fetched for this article. ICC's A2L list does not name R-410A. Johnson Controls' whitepaper calls R-410A an A1-classified refrigerant. A1, on the same paper's class table, is the no-flame-propagation column.
ICC lists R-32 among the A2L refrigerants on its transition page. Johnson Controls names R-32 next to R-454B as a refrigerant the industry is moving equipment toward. This page does not print a GWP for R-32, because the pages fetched today did not put a GWP number on R-32 in a sentence this article will quote.
No. R-454B is one name on ICC's A2L list. R-32 is another. A2L is the safety class. 454B is one refrigerant in that class. They are not the same word.